power: supply: sc27xx: Fix the incorrect formula when converting capacity to coulomb counter



We should multiply the calibrated current data (cur_1000ma_adc) when
converting current capacity (mAh) to coulomb counter, which can get
an accurate coulomb counter from the fuel gauge controller.

Signed-off-by: default avatarBaolin Wang <baolin.wang@linaro.org>
Signed-off-by: default avatarSebastian Reichel <sebastian.reichel@collabora.com>