iio: ABI: temperature: Unify documentation for thermocouple fault detection.



Kernel documentation for a given ABI element should not be duplicated
in multiple files, so pull them into one higher level documentation file.

Signed-off-by: default avatarJonathan Cameron <Jonathan.Cameron@huawei.com>
Cc: Navin Sankar Velliangiri <navin@linumiz.com>
Cc: Paresh Chaudhary <paresh.chaudhary@rockwellcollins.com>
Reviewed-by: default avatarMauro Carvalho Chehab <mchehab@kernel.org>
Link: https://lore.kernel.org/r/20220626165511.602202-2-jic23@kernel.org
parent 295cc426
Loading
Loading
Loading
Loading
+0 −12
Original line number Diff line number Diff line
What:		/sys/bus/iio/devices/iio:deviceX/fault_ovuv
KernelVersion:	5.11
Contact:	linux-iio@vger.kernel.org
Description:
		Overvoltage or Undervoltage Input fault. The internal circuitry
		is protected from excessive voltages applied to the thermocouple
		cables at FORCE+, FORCE2, RTDIN+ & RTDIN-. This circuitry turn
		off when the input voltage is negative or greater than VDD.

		Reading returns '1' if input voltage is negative or greater
		than VDD, otherwise '0'.

What:		/sys/bus/iio/devices/iio:deviceX/in_filter_notch_center_frequency
KernelVersion:	5.11
Contact:	linux-iio@vger.kernel.org
+10 −23
Original line number Diff line number Diff line
What:		/sys/bus/iio/devices/iio:deviceX/fault_oc
KernelVersion:	5.1
Contact:	linux-iio@vger.kernel.org
Description:
		Open-circuit fault. The detection of open-circuit faults,
		such as those caused by broken thermocouple wires.
		Reading returns either '1' or '0'.

		===  =======================================================
		'1'  An open circuit such as broken thermocouple wires
		     has been detected.
		'0'  No open circuit or broken thermocouple wires are detected
		===  =======================================================

What:		/sys/bus/iio/devices/iio:deviceX/fault_ovuv
KernelVersion:	5.1
Contact:	linux-iio@vger.kernel.org
Description:
		Overvoltage or Undervoltage Input Fault. The internal circuitry
		is protected from excessive voltages applied to the thermocouple
		cables by integrated MOSFETs at the T+ and T- inputs, and the
		BIAS output. These MOSFETs turn off when the input voltage is
		negative or greater than VDD.
		cables. The device can also detect if such a condition occurs.

		Reading returns either '1' or '0'.
		Reading returns '1' if input voltage is negative or greater
		than VDD, otherwise '0'.

		===  =======================================================
		'1'  The input voltage is negative or greater than VDD.
		'0'  The input voltage is positive and less than VDD (normal
		     state).
		===  =======================================================
What:		/sys/bus/iio/devices/iio:deviceX/fault_oc
KernelVersion:	5.1
Contact:	linux-iio@vger.kernel.org
Description:
		Open-circuit fault. The detection of open-circuit faults,
		such as those caused by broken thermocouple wires.
		Reading returns '1' if fault, '0' otherwise.