Skip to content
Commit 075eaef8 authored by H Hartley Sweeten's avatar H Hartley Sweeten Committed by Greg Kroah-Hartman
Browse files

staging: comedi: pcl711: remove unnecessary test of 'board->is_8112'



At the end of an asynchronous command, the analog input is returned
to software triggered mode. For the non-8112 style boards the mode
PCL711_MODE_DEFAULT and PCL711_MODE_SOFTTRIG are identical. Just set
the mode to PCL711_MODE_SOFTTRIG and remove the test.

Signed-off-by: default avatarH Hartley Sweeten <hsweeten@visionengravers.com>
Reviewed-by: default avatarIan Abbott <abbotti@mev.co.uk>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>
parent fd8b1b8c