Commit 08a0c6df authored by Lukas Wunner's avatar Lukas Wunner Committed by Greg Kroah-Hartman
Browse files

serial: pl010: Drop CR register reset on set_termios

pl010_set_termios() briefly resets the CR register to zero.

Where does this register write come from?

The PL010 driver's IRQ handler ambauart_int() originally modified the CR
register without holding the port spinlock.  ambauart_set_termios() also
modified that register.  To prevent concurrent read-modify-writes by the
IRQ handler and to prevent transmission while changing baudrate,
ambauart_set_termios() had to disable interrupts.  That is achieved by
writing zero to the CR register.

However in 2004 the PL010 driver was amended to acquire the port
spinlock in the IRQ handler, obviating the need to disable interrupts in
->set_termios():
https://git.kernel.org/history/history/c/157c0342e591



That rendered the CR register write obsolete.  Drop it.

Cc: Russell King <rmk+kernel@armlinux.org.uk>
Signed-off-by: default avatarLukas Wunner <lukas@wunner.de>
Link: https://lore.kernel.org/r/fcaff16e5b1abb4cc3da5a2879ac13f278b99ed0.1641128728.git.lukas@wunner.de


Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>
parent 556172fa