net: phy: DP83TC811: Fix WoL in config init to be disabled
The WoL feature should be disabled when config_init is called and the
feature should turned on or off when set_wol is called.
In addition updated the calls to modify the registers to use the set_bit
and clear_bit function calls.
Fixes: 6d749428788b ("net: phy: DP83TC811: Introduce support for the
DP83TC811 phy")
Signed-off-by:
Dan Murphy <dmurphy@ti.com>
Signed-off-by:
David S. Miller <davem@davemloft.net>