Commit 73314772 authored by LI Qingwu's avatar LI Qingwu Committed by Jonathan Cameron
Browse files

iio: accel: bmi088: Modified the scale calculate



The units after application of scale are 100*m/s^2,
The scale calculation is only for the device
with the range of 3, 6, 12, and 24g,
but some other chips have a range of 2, 4, 6, and 8g.

Modified the scales from formula to a list, the scales in the list are
calculated as 9.8/32768*pow(2,reg41+1)*1.5, refer to datasheet 5.3.4.
The new units after the application of scale are m/s^2.

Reviewed-by: default avatarAlexandru Ardelean <ardeleanalex@gmail.com>
Signed-off-by: default avatarLI Qingwu <Qing-wu.Li@leica-geosystems.com.cn>
Link: https://lore.kernel.org/r/20220526133359.2261928-2-Qing-wu.Li@leica-geosystems.com.cn


Signed-off-by: default avatarJonathan Cameron <Jonathan.Cameron@huawei.com>
parent f0ca36b0